Cold Storage

Cold Storage applications create one of the most hostile environments to which insulation can be exposed due to large temperature differentials and associated severe water vapour pressures. Twiga Insul is the most patronized product for cold storage application in India.

Apart from its thermal performance (with Twiga Insul, excellent thermal conductance value (U Value) can be achieved), another major check point is Fire Safety of material in Cold Storage for Partition and Ceiling/ Roof Applications.

Glasswool conforms all the stringent fire standards including BS 476 (part 4,5,6 and7).

-BS 476 Part 4: Non combustible

-BS 476 Part 5: Class P (highest class in Ignitibility test)

-BS 476 Part 6: Fire propagation (main index<12, sub index<6)

-BS 476 Part 7: Class 1 (Surface Spread of Flame is NIL)

Twiga Glasswool is completely fire safe material and it is Class ‘O’ and Class 1 material which is the highest rating in fire standard. * (LINK TO Twiga Insul)

 

Prevailing Specification

Type of Insulation Material Wall Ceiling/ roof U value = 0.24W/ m2K Floor U value = 0.29 W/ m2K
External U value = 0.27W/ m2K Partition U value = 0.58 W/ m2K
  Density Kg/ m3 K (at 100C) W/mK Thickness MM Thickness MM Thickness MM Thickness MM
Glasswool Insulation 32 0.33 125 50 125 100

Alternative Specification proposed by Twiga for Cold Storage application

Type of Insulation Material Wall Ceiling/ roof U value = 0.24W/ m2K Floor U value = 0.29 W/ m2K
External U value = 0.27W/ m2K Partition U value = 0.58 W/ m2K
  Density Kg/ m3 K (at 100C) W/mK Thickness MM Thickness MM Thickness MM Thickness MM
Glasswool Insulation 32 0.33 125 50 125 100
Glasswool Insulation 27 0.031 125 50 125 100
Glasswool Insulation 32 0.030 125 50 125 100